Maintenance, English, A) (b) (c) (d) (c) (b) – Wagner Flexio 690 Sprayer User Manual

Page 15: Cleaning the filters, Cleaning the air valve tube

Advertising
background image

English

© Wagner Spray Tech. - All Rights Reserved

15

Maintenance

Cleaning the Filters:

IMPORTanT: Before every use, you should

inspect the air filters in the turbine to see if it

is excessively dirty. If it is dirty, follow these

steps to replace it.
IMPORTanT: never operate your unit

without the air filters. Dirt could be sucked in

and interfere with the function of the unit.

1. Press the tabs on each side of the turbine to

remove the filter covers.

2. Remove the dirty filters from the turbine and

replace with new ones. The smooth side of the

air filter must be placed toward the turbine.

Secure the covers back onto the turbine.

Cleaning the Air Valve Tube

note: If paint has entered the air tube, proceed as

follows.

1. Pull the air tube (a) at the top from the nozzle. Screw

off the valve cover (b). Remove the valve seal (c).

Clean all the parts carefully. Make sure to remove any

material from valve seal housing area (d).

IMPORTanT: The air tube and valve seal (c) are only

solvent-resistant to a limited extent. Do not immerse

in solvent, only wipe.

2. Place the valve seal (c) in the valve cover (b) with the

pin facing into the tube.

note: Installing the valve seal into the valve cover will

be much easier if the valve cover is inverted.

3. Turn the nozzle upside down and screw on the valve

cover (with valve seal inside) from underneath.

note: Turning the nozzle upside down will prevent

the valve seal from falling out of the valve cover during

reinstallation.

4. Place the air tube on the valve cover and on the nipple

at the nozzle.

(a)

(b)

(c)

(d)

(c)

(b)

1

2

4

3

Advertising