Horner APG XL6 OCS User Manual
Page 69

MAN0883-05-EN
CH.12
March 4, 2010
Page 69 of 135
#1037
Set Beeper
The Set Beeper Sub-Menu displays one System Setting, which is editable
Beeper enable: Yes (default)= Enables beeper No = Disables beeper (does NOT affect ladder
access)
Set Screen
The Set Screen Sub-Menu displays four System Settings, all of which are editable
Saver enable: Yes = Enable screen saver
No (default) = Disable screen saver
Timeout (min): 5 - 1200 = Amount of time in minutes to expire with NO touch activity before
activating screen saver (black screen)
Popup Status: Off (default) = Disable popup status
Warning = Display popup status only if controller status changes to NOT Ok or
NOT Run mode.
ON = Display popup status on any controller status change.
Update Time (mS): 2 - 50 = Maximum amount of time to allow for graphics update per scan