Timer/counters, Interfaces, Usart – Atmel AVR XMEGA 8/16-bit High Performance Low Power Flash Microcontrollers User Manual

Page 9: Twi (the two wire interface), Bi-directional 2-wire bus communication, • i, Awex, Timer/counter base counter, Hi-r es por ts clk

Advertising
background image

www.atmel.com

Timer/Counters

All AVR XMEGA Timer/Counter modules are 16-bit with input
Capture and Pulse Width Modulation (PWM) functionality. Up
to 128 MHz PWM is possible from internal PLL by using the Hi-
Res extension. Using the Event System and Advanced Waveform
Extension (AWeX) and high resolution extention, implementation of
advanced motor control (AC, BLDC, SR, and Stepper) and power
control applications is made easy.

interfaces

AVR XMEGA comes with various interfaces that combined with DMA or Event System creates a powerful and
fast communication platform.

USART

Full asynchronous and clocked synchronous
operation.
• Fractional BAUD Rate Generator
• Master SPi mode
• iRCOM module for irDA Compliance
• Up to 4 Mbps communication

SPI

Fast full duplex synchronous serial communication
• Master and Slave Operation
• Up to 16 Mbps communication

EBI

External Bus interface, for easy access to
• SRAM
• SDRAM
• External peripherals (e.g. LCDs)
• Memory mapped devices

TWI (The Two Wire Interface)

Bi-directional 2-wire bus communication,
• i

2

C and SMBus compliant

• Slave operates in all Sleep Modes
• Full 100 kHz and 400 kHz support
• Master and Slave operation

Normal mode of operation, counting up or down

CNT

BOT

MAX

"update"

PER

CNT written

DIRECTION

CNT

MAX

New Period written to

PERBUF that is higher

than current CNT

New Period written to

PERBUF that is lower

than current CNT

"update"

"write"

New PER is updated

with PERBUF value.

BOT

AWeX Dead Time Insertion (DTI) with separate high side and

low side period

DTI CNT

T/C output

high side output

low side output

t

low side

t

high side

T

events

CNT

PER

BOT

Capture 0

Capture 1

Capture 2

Capture 3

"capture"

Period (T)

external signal

events

CNT

MAX

BOT

"capture"

Changing the period with buffering in dual slope mode

Input capture of pin change using the Event System

Frequency capture of an external signal

Timer/Counter

Base Counter

Timer Period(PER)

Counter(CNT)

Logic Control

Compare/Capture Channel n

Capture Control

Waveform

Generation

Comparator

Buffer

AWeX

Dead-Time

Insertion

Pattern Generator

Fault Protection

clk

PER4

H

i-R

es

Por

ts

clk

PER

Prescaler

Event System