Barometer needle shows incorrect reading:

A. Tap the barometer glass lightly and review the reading.
B. Adjust the slot head screw in the back of the movement, turning either

left or right to bring the needle to the correct reading. Never turn this screw

more than one rotation to avoid damage to the movement.
C. If A or B do not resolve the problem, call Customer Service at 1-800-638-0428.

VII. Barometer/ Thermometer Instructions

Please see instructions above (VI) to adjust barometer.

Thermometer has been preadjusted and calibrated in a temperature controlled

environment at the factory.

VIII. Thermometer Instructions

This bimetal thermometer works on the principle that different metals

contract and expand to different degrees when exposed to temperature

changes. This thermometer has been preadjusted and calibrated in a

temperature controlled environment at the factory.
To Recalibrate:

On the back, in the center of the movement, you will see an adjustment

port. Insert a small eyeglass flathead screwdriver into the slot. Hold the unit

vertically as you make the adjustment. Gently turn the mechanism until the

pointer indicates the correct temperature.