Weems and Plath Endurance II 135 Barometer/Thermometer User Manual

Page 12

Advertising
background image

Your barometer can be mounted indoors or outdoors as the pressure will

be the same in either location. At sea level, the normal atmospheric pressure

is about 30 inches, very rarely will the needle ever exceed 30.5 or drop below

29.5. Sometimes it is possible for the pressure to change only one or two tenths

of one inch over a week. Even a storm may cause only a half inch change. The

words Rain, Change, and Fair are on the barometer dial as a traditional graphic

decoration, not to be used as a weather predictor.
Barometer Specifications

The barometer measures atmospheric pressure in kPa/inch Hg or hPa/mm Hg

Measurement range: 940-1060Pa

Precision: 990-1030 hPa:+/-3hPa

960-990 hPa/1030-1060 hPa:+/-5hPa
Barometer Troubleshooting
Barometer needle does not move:

A. Often barometric pressure remains

steady for extended periods of time. Watch

for a few days to see if any changes occur.
B. If no changes occur after one week, then

do the following test: Place the barometer

in a clear plastic bag. Hold the opening of

the bag closed tightly to trap the air inside.

Push on the bag to create air pressure

which should cause the needle to move.
C. If the needle does not move after trying A & B, call Customer Service 1-800-638-0428.