The vertical axis corresponds to air pressure values in mb. One dash or one space
corresponds to 1 mb.

TIme INTerVal

Zoom

mB sCale

1 min

2 hours

8 mb

2 min

4 hours

10 mb

3 min

6 hours

16 mb

6 min

12 hours

20 mb

12 min

24 hours

20 mb

24 min

48 hours

30 mb

This function allows you to select the ZOOM on the chart screen with
a choice of 2 hours, 4 hours, 6 hours, 12 hours, 24 hours or 48 hours.

• Press the

Zoom

, button, xh fl ashes on the screen (x corresponding to the value of the

zoom selected.)

• Use the

+

-

buttons to change the ZOOM value.

• Press on

oK

to confi rm.

The display is composed of a series of points.