Cooling – Samlex America PST-120-12 User Manual

Page 9

Advertising
background image

8 | SAMLEX AMERICA INC.

SAMLEX AMERICA INC. | 9

LeD StAtUS

inDicAtoR

StAtUS oF inVeRteR

StAtUS oF USB PoRt

OFF

AC output is available

No output from USB port due to:

- Over voltage ≥6.2V
- USB section is defective

AC output is not available

No DC input, check:

- 12V Plug Adaptor (8) is firmly
connected to the 12 VDC power
source
- 15A fuse (5) is not blown

gREEN

AC output is available

USB output is available

ORANgE

AC output is not available due to operation of one

or more of the following protections:

- Over temperature
- Low DC input voltage
- High DC input voltage

USB output is available

RED

AC output is not available due to operation of one

or more of the following protections:

- Over temperature
- Low DC input voltage
- High DC input voltage

No output from USB port due to:

- Over voltage ≥6.2V
- USB section is defective

seCtIOn 3 |

Installation & Operation

cooling

- The inverter has a temperature controlled fan for cooling.

- The fan will start once the temperature of the hot spot inside the unit exceeds

70°C / 158°f. note: In cooler ambient temperature and/or at no/low loads, the hot spot
may not reach 70°C / 158°f and hence, the fan will be off.

- If the fan fails, or if adequate cool air change is not available, temperature of hot spot

will continue to rise and at ≥ 105°C / 221°f, AC output will be shut down. AC output
will be restored when the unit cools down sufficiently.

- Place the unit in a cool, well ventilated space that has adequate cool replacement

air (fig. 3.1).