Campbell Scientific 253-L and 257-L (Watermark 200) Soil Matric Potential Sensors User Manual

Page 32

Advertising
background image

253-L and 257-L Soil Matric Potential Sensors

9: Z=X*F (P37)

1: 6

-- X Loc [ WP_kPa_1 ]

2: 0.0106 F

3: 6

-- Z Loc [ WP_kPa_1 ]


10: Z=F x 10^n (P30)

1: 34.21

F

2: 0

n,

Exponent

of

10

3: 16

Z Loc [ Const_1 ]


11: Z=X-Y (P35)

1: 16

X Loc [ Const_1 ]

2: 1

-- Y Loc [ T107_C_1 ]

3: 16

Z Loc [ Const_1 ]


12: Z=X+Y (P33)

1: 6

-- X Loc [ WP_kPa_1 ]

2: 16

Y Loc [ Const_1 ]

3: 6

-- Z Loc [ WP_kPa_1 ]


13: Z=X*F (P37)

1: 6

-- X Loc [ WP_kPa_1 ]

2: 1.062

F

3: 6

-- Z Loc [ WP_kPa_1 ]


14: Z=X-Y (P35)

1: 6

-- X Loc [ WP_kPa_1 ]

2: 11

-- Y Loc [ kOhms_1 ]

3: 6

-- Z Loc [ WP_kPa_1 ]


15: Z=F x 10^n (P30)

1: 1.306

F

2: -2

n,

Exponent

of

10

3: 17

Z Loc [ Const_2 ]


16: Z=X*Y (P36)

1: 6

-- X Loc [ WP_kPa_1 ]

2: 17

Y Loc [ Const_2 ]

3: 6

-- Z Loc [ WP_kPa_1 ]


17: Z=X/Y (P38)

1: 11

-- X Loc [ kOhms_1 ]

2: 6

-- Y Loc [ WP_kPa_1 ]

3: 6

-- Z Loc [ WP_kPa_1 ]


;End of measurement and processing loop
18: End (P95)

;Turn off multiplexer
19: Do (P86)
1: 51

Set

Port

1

Low

26

Advertising