AM16/32A Relay Analog Multiplexer

CR10X Example Program – Thermocouple and Soil Block
Measurement

CR10(X)

AM16/32

12V

G

MUXPOWER

SHIELD

MUXSIGNAL

SHIELD

1K 0.1%

G

C1

C2

1H

1L

EX 1

2L

AG

EX 2

2H

AG

GND

12V

GND

RES

CLK

COM ODD H

107

COM ODD L

COM EVEN H

COM EVEN L

ODD H

SETS 1-16

SETS 1-16

ODD L

EVEN H

EVEN L

COM

G

32

FIGURE 20. Thermocouple and Soil Block Measurement for CR10X Example

*1

T

33 LOCATIONS ALLOCATED TO INPUT STORAGE)

able 1 Programs

1: 60

Sec. Execution Interval


REFERENCE TEMPERATURE FOR THERMOCOUPLES
1: Temp 107 Probe (P11)
1: 1

Rep

2: 4

IN

Chan

3: 1

Excite all reps w/EXchan 1

4: 1

Loc

[:REFTEMP

]

5: 1

Mult

6: 0

Offset


ENABLES MULTIPLEXER
2: Do (P86)
1: 41

Set high Port 1


BEGINS MEASUREMENT LOOP
3: Beginning of Loop (P87)
1: 0

Delay

2: 16

Loop

Count

AM16/32A