Campbell Scientific AM16/32B Relay Multiplexer User Manual

Page 29

Advertising
background image

AM16/32B Relay Multiplexer

Input

locations

1 2 3 4 5 6

First

pass:

1 2

Second

pass: 3 4 sensor

Third

pass:

5 6 numbers

ying the

on

A potential drawback of this technique is that sequential sensors (i.e., those
input to the same SET) will not have sequential input locations.

#5 Measure — Enter the instruction needed to measure the sensor(s) (see
Section 6, Sensor Hookup and Measurement Examples). The input location
parameter of a measurement instruction is indexed if a (--) appears to the right
of the input location. Index an input location by pressing “C” after ke
location or by pressing F4 in Edlog while cursor is on the input locati
parameter. Indexing causes the input location to be incremented by 1 with
each pass through the loop. This allows the measurement value to be stored in
sequential input locations. Instruction Step Loop Index (P90), as explained
above, allows the indexed input location to be incremented in integer steps
greater than 1.

If more than the datalogger’s default number of input locations
are required, then additional input locations must be assigned
using the datalogger *A mode. Consult your datalogger manual
for details.

#6 Optional Processing — Additional processing is sometimes required to

ore efficient if this

ond loop can be used

ng, if necessary

NOTE

convert the reading to the desired units. It may be m

essing is done

op. A sec

proc

outside the measurement lo

.

for processi

19