21x, and cr7 dataloggers – Campbell Scientific AM16/32B Relay Multiplexer User Manual

Page 31

Advertising
background image

AM16/32B Relay Analog Multiplexer

EXAMPLE “2x32” MODE PROGRAMS — GENERALIZED PROGRAM LOOPS FOR THE

CR23X, 21X, CR10(X), AND CR7.

21X SAMPLE PROGRAM

CR7 SAMPLE PROGRAM

*

1

Table 1

Programs

01: 60 Sec.

Execution

Interval

;ACTIVATE MULTIPLEXER

1: Set Port (P20)

1:

1

Set

high

2:

1

Port

Number

;BEGIN MEASUREMENT

;LOOP

2: Beginning of Loop (P87)

1:

0

Delay

2: 32

Loop

Count

CLOCK PULSE/DELAY

3: Excitation with delay (P22)

1:

1

EX

Chan

2:

1

Delay

w/EX

(units=

.01

sec)

3:

1

Delay

after

EX

(units=

.01

sec)

4: 5000

mV

Excitation

4: User Specified Measurement

Instruction

;END MEASUREMENT

;LOOP

5: End (P95)

;DEACTIVATE

;MULTIPLEXER

6: Set Port (P20)

1:

0

Set

low

2:

1

Port

Number

*

1

Table 1

Programs

01: 60 Sec.

Execution

Interval

;ACTIVATE MULTIPLEXER

1: Set Port (P20)

1:

1

Set

high

2:

1

EX

Card

3:

1

Port

No.

;BEGIN MEASUREMENT

;LOOP

2: Beginning of Loop (P87)

1:

0

Delay

2: 32

Loop

Count

;CLOCK PULSE/DELAY

3: Excitation with delay (P22)

1:

1

EX

Chan

2:

2

EX

Chan

3:

1

Delay

w/EX

(units=

.01

sec)

4:

1

Delay

after

EX

(units

=

.01

sec)

5: 5000

mV

Excitation

4: User Specified Measurement

Instruction

;END MEASUREMENT

;LOOP

5: End (P95)

;DEACTIVATE

;MULTIPLEXER

6: Set PortP20

1:

0

Set

low

2:

1

EX

Card

3:

1

Port

No.

CR10(X), CR23X

SAMPLE PROGRAM

ELAY

on with Delay (P22)

.01

sec)

0

n

*

1

Table 1

Programs

01: 60 Sec.

Execution

Interval

;ACTIVATE MULTIPLEXER

1: Do (P86)

1: 41

Set

high

Port

1

;BEGIN MEASUREMENT

;LOOP

2: Beginning of Loop (P87)

1:

0

Delay

2: 32

Loop

Count

;CLOCK PULSE

3: Do (P86)

1:

72

Pulse Port 2

;D

4: Excitati

1:

1

EX

Chan

2:

0

Delay

w/EX

(units=.01

sec)

3:

1

Delay

after

EX

(units=

0:

mV

Excitatio

5: User Specified Measurement

Instruction

;END MEASUREMENT

;LOOP

6: End (P95)

;DEACTIVATE

;MULTIPLEXER

7: Do (P86)

1: 51

Set

low

Port

1

FIG

loops for CR23X,

CR10(X), 21X, and CR7 dataloggers

URE 5-3. Example “2x32” mode program

21

Advertising