Appendix A. CS I/O Port

The CS I/O port is Campbell Scientific's input/output port. It is not a standard
RS-232 pin-out. The following table provides pin-out information on the port
when connected to a datalogger.

Pin


Name

Signal
Type


Description

1

5 V (supplied by the
datalogger)

Input

Not used by NL100/105

2

Signal Ground

Provides reference for voltage
levels

3

Ring

Output

Raised by a NL100/105 to put
the datalogger into the
telecommunications mode

4

RXD

Output

Serial data transmitted to the
datalogger

5

Modem Enable

Input

Raised by the datalogger when
it determines that the
NL100/105 raised the ring line

6 Synchronous

Device

Enable

Input

Used by the datalogger to
address the NL100/105 when
the NL100/105 is configured
as a synchronous device

7

Clock/Handshake

Input

Used by the datalogger with
SDE and TXD lines to address
and transfer data to
synchronous devices

8

12 V (supplied by the
datalogger)

Not used by the NL100/105

9 TXD

Input

Serial

data received from the

datalogger

A-1