2 fill-and-stop mode, 3 mixed modes, Fill-and-stop mode – Campbell Scientific NL115 Ethernet Interface and CompactFlash Module User Manual

Page 27: Mixed modes

Advertising
background image

NL115 Ethernet and CompactFlash

®

Module

PROGRAM

'CR1000

Public temp

DataTable (Table1,1,-1)
CardOut (0, -1)
Maximum (1,temp,FP2,False,False)
Minimum (1,temp,FP2,False,False)
EndTable

BeginProg
Scan(1,SEC,3,0)
PanelTemp(temp,250)
CallTable Table1
NextScan
EndProg

7.3.2.2 Fill-and-Stop Mode

The following program outputs a sample of the panel temperature to the card

once a second. The first parameter of the

CardOut() instruction is 1, which

sets the table on the card to fill-and-stop mode. The second parameter (1000)

is the number of records which will be written before the table is full and data

storage stops. Once 1000 records have been stored, data storage to the

specified table on CRD: and CPU: datalogger memory drives will stop.

PROGRAM

'CR1000

Public temp

DataTable (Table1,1,1000)
CardOut (1,1000)
Sample(1,temp,IEEE4)
EndTable

BeginProg
Scan(1,SEC,3,0)
PanelTemp(temp,250)
CallTable Table1
NextScan
EndProg

To restart data storage to the fill-and-stop table, the table must be reset.

To reset a table after a fill-and-stop table has been filled and stopped, either use

the reset button in LoggerNet (LN Connect | Datalogger | Station Status | Table

Fill Times, Reset Tables) or use the CRBasic

ResetTable() instruction.

7.3.2.3 Mixed Modes

The following program stores four data tables to the card. The first two tables

will output samples of the panel temperature and battery voltage to the card

once a second. The first parameter of the

CardOut() instruction is 1, which

sets the tables on the card to fill-and-stop mode. The second parameter is

1000, so 1000 records will be written to each table before stopping.

21

Advertising