background image

NL115 Ethernet and CompactFlash

®

Module

4.2 Communicating via Ethernet

4.2.1 Step 1: Configure Datalogger

a. Connect serial cable from PC COM port to the datalogger RS-232 port.

b. Open Campbell Scientific’s Device Configuration Utility. Select the

device type of the datalogger (CR1000 or CR3000), the appropriate serial

port, and baud rate. Connect to the datalogger.

c. Under the TCP/IP tab, input the IP Address, Subnet Mask, and IP

gateway. These values should be provided by your network

administrator.

FIGURE 4-2. DevConfig setup

d. Press the Apply button to save the changes and then close the Device

Configuration Utility.

A temporary IP address may be obtained from a DHCP server.

For more information, see Section 7.1.8, DHCP.


The NL115 must be connected to the datalogger before

configuring the datalogger with the Device Configuration Utility.

If it is not connected, the TCP/IP settings will not be displayed.

NOTE

NOTE