Section 5. timer aerator control – Campbell Scientific PONDVIEW Real-Time Monitoring & Control Software User Manual

Page 29

Advertising
background image

5-1

Section 5. Timer Aerator Control

In addition to the aerators being controlled automatically be the condition of
the dissolved oxygen, and manually by the operator, they can also be
controlled by a timer.

Like the manual mode of control, the time mode of control overrides the
automated control based on the condition of the dissolved oxygen. The timers
will turn the aerator on and off at a user specified time regardless of the
condition of the dissolved oxygen.

Click on the desired aerator. Click on the Timer Status button; this will pop up
the Paddle Wheel Timer Select screen. In this screen enter the desired start and
stop times. These must be entered in military times. After a value is entered in
the Set Start Time and Set Stop Time locations, the corresponding button must
be pressed in order to send these values to the CR10X-TD.

Even with the start and stop values sent to the CR10X-TD, the timer function is
not active until the Timer Status Button is turned ON. To turn the button on,
click the Timer Status button with the right mouse. Select ON. The timer is
now active and will control the aerators based on the times entered.