2. Check your LoggerNet setup.

a. Make sure the port number at the end of the IP address matches the

port number of the Raven (e.g., 3001, see FIGURE 7-1).

FIGURE 7-1. Device Port configuration

b. Try adding a few seconds to the extra response time on the IP Port in

LoggerNet (you should not need more than 5 seconds).

c. If you are trying to communicate to a PakBus datalogger:

i. Verify the PakBus address in the setup screen matches that of the

datalogger.

ii. If you have multiple PakBus networks/ports setup in LoggerNet,

uncheck the ‘PakBus Port Always Open’ options on all PakBus
ports.