3 setting station id – Campbell Scientific RF310, RF312, RF313 Narrowband Radios User Manual
Page 24

Section 3. Radiotelemetry Network Components
3-2
RF310M
FIGURE 3-1. The RF310M Modem
TABLE 3-1. A Sample of Station ID Numbers and
the Corresponding Switch Settings
Station
Switch Settings
ID
1234
56789
0
0000
0000X
10
0101
0000X
20
0010
1000X
30
0111
1000X
40
0001
0100X
50
0100
1100X
60
0011
1100X
70
0110
0010X
80
0000
1010X
90
0101
1010X
100
0010
0110X
110
0111
0110X
120
0001
1110X
130
0100
0001X
*Station ID 255 is reserved for phone-to-RF base stations.
The RF310M is shipped with the switch set for the RF310M-ME state and
station ID of 1.
3.1.3 Setting Station ID
Each RF310M, including the one in the RF base station, must have a unique
Station ID. The station ID is similar to a phone number. This allows one base
station to communicate with any one particular field station.
The Station ID can be any number from 1 to 255. The Station ID is set with the
switch inside the RF310M. The first eight dip switches are used to set the
Station ID. Table 3-1 shows the switch settings for several Station ID numbers.
Appendix A shows all possible Station ID numbers. The dip switches can