Campbell Scientific RF310, RF312, RF313 Narrowband Radios User Manual
Page 67

Appendix F. Specifications
F-3
12.5 kHz CP
< 40Db with PSOPH
Receiver Response Time
<16 mS
Squelch Opening Range
RF level for 6 to 14 dB Sinad
Squelch Closing Range (Hysteresis)
0 - 6 dB Sinad @ Nominal Condition
Squelch Attack Time:
RF Level at Threshold
RF Level at Threshold + 20 dB
< 40 ms
<30 mS
Squelch Decay Time
5 mS Min., 20 mS. Max.
Antenna Socket Input Match
10 dB Return Loss
L.O. frequency Temperature Stability
1
st
<5ppm, 2
nd
< 15ppm from -30 to 60
°C
L.O. Frequency Aging rate
-2ppm/year
Specifications
Reference Crystal
Frequency
12.8 MHz
Holder Type
HC-18
Temperature Characteristic
-5.0 ppm from -30 C to +60 C
Aging Rate
< 2 ppm/year in 1
st
Year, < 1 ppm/year thereafter
Lock Time
< 10 mS
TX to RX
< 20 (No Power Saving)
RX to TX
< 20
Due to continuing research and development the company reserves the right to
alter these specifications without prior notice.