2 controlled device connections – Campbell Scientific SDM-CD8S 8 Channel Solid State DC Control Module User Manual

Page 10

Advertising
background image

SDM-CD8S 8 Channel Solid State DC Control Module

EXTERNAL

8 TO 26 VDC

+ —

SDM-CD8S

DATALOGGER

GND

C1
C2
C3


Connection to External Supply

SDM-CD8S

DATALOGGER

12 V
C1
C2
C3

GND


Connection to Datalogger Supply

FIGURE 2. Connection block diagrams

TABLE 1. Datalogger to SDM-CD8S Connections

SDM-CD8S Datalogger

Function

PWR

12 V on datalogger or
8 to 26 V external supply

Power

Logic Gnd

Gnd

Common ground

C1

C1 (Control Port 1)

Data

C2

C2 (Control Port 2)

Clock

C3

C3 (Control Port 3)

Enable

4.1.2 Controlled Device Connections

In most applications, the SDM-CD8S acts as a switch (controllable break) in
the ground return of the circuit powering the controlled device. Figure 3
shows an example.

4