Campbell Scientific SDM-INT8 8-Channel Interval Timer User Manual

Page 29

Advertising
background image

SDM-INT8 8 Channel Interval Timer

3: Beginning of Loop (P87)

loop to make a 10 sec.

1: 1

Delay

delay

2: 20

Loop

Count

4: End (P95)

end of loop

5: Do (P86)

set the output

1: 10

Set high Flag 0 (output)

flag

6: Real Time (P77)

time tag the output

1: 11

Hour-Minute,

Seconds

7: Do (P86)

retrieve INT8 data

1: 1

Call

Subroutine

1

8: Do (P86)

initialize flag 2

1: 22

Set low Flag 2

9: End Table 1 (P)

*Table 3 Subroutines

1: Beginning of Subroutine (P85)

1: 1

Subroutine

Number

2: SMD-INT8 (Extended) (P101)

1: 0

Address

Option

2: 0001

Chan8765=HLrise/HLrise/HLrise/HLfall/

3: 0000

Chan4321=HLrise/HLrise/HLrise/HLrise/

4: 0003

Chan8765=none/none/none/TsinceP/

5: 0502

Chan4321=none/C2sincel/none/kHz/

6: 20--

Edges of Chan 1 in events mode

7: 1

Loc: <--- Ignored in "Events" Option

8: 1

Mult

9: 0

Offset

3: End (P95)

7.2.2 Wind Speed Measurements - Execution Interval Averaging

The INT8 is used to make 1 second averages of frequencies from 6 RM Young
Wind Monitors. Frequencies are converted to wind speed in m/s, and place in
Input Locations 1 - 6. Wind directions are then measured, scaled, and placed
in Input Locations 7-12. Programming does not output the data to the
dataloggers' Final Storage.

Note that wind speeds of less than 0.2 m/s, corresponding to 2 Hz, will read 0
if a cycle of the Wind Monitor does not get completed within the 1 second
execution interval.

23

Advertising