depth has been reached. Note: If the access tube spins while augering, engage the metal
“tooth” on the tripod by turning the lever located on the tripod cylinder.
12. Use the auger cleaning tool to remove the soil from the auger head. Do not empty the
augered soil near the access tube as it may change the infiltration rate of irrigation and
rainfall. Dispose of the soil away from the monitoring site.
13. Select the Heavy duty dolly and re-insert it in the top of the access tube.
14. Turn the lever to make sure that the metal tooth on the tripod cylinder is “disengaged”. Take
the sledge hammer and hit the dolly to drive the access tube further into the pre-drilled hole.
15. When you reach the bottom of the pre-drilled hole, hammering becomes noticeably more
difficult. Remove the dolly.