Campbell Scientific Sentek EnviroSCAN Access Tube Installation Guide User Manual
Page 40

Installing EnviroSCAN, EnviroSM ART & Diviner 2000 access tubes
© Sent ek Pt y Lt d
Page 37
Additional items for difficult stony soils
Item
Part
Number
Open Centre Tungsten Tip Auger 61.0 mm
70045
Rock Breaker 54.0 mm
70025
Auger extension rods re-enforced 1.0 m
70015
Miscellaneous Items (Installer to supply)
Length of rope – to tie branches or vines temporarily out of the way so that they do not get damaged or
interfere with the augering process.
Duck boards – to prevent soil campaction around the access tube during the installation process.
Measuring tape – to measure to the required depth
Marking pen
2 x 10 litre (2 gallon) buckets – to collect the augered soil and remove it from the site, and to mix the slurry
in.
Notepad and pencil - to record the depth and texture variation throughout the soil profile and any other site
information.
Paint stirrer with electric drill attachment – for mixing the slurry.
Cordless electric drill – to attach to the paint stirrer for mixing the slurry.
Spatula or broad knife – to chip away excess slurry
Slurry Components
Grey cement
Kaolinite (potters clay as fine powder)
Water