A windsonic4, 10. wiring, Cr10(x) program example – Campbell Scientific WINDSONIC 2-D Sonic Wind Sensors User Manual
Page 25
WindSonic Two-Dimensional Sonic Anemometer
7.4.1 Example CR10X (Edlog) Datalogger Program for Measuring a
WindSonic4
TABLE 7-10. Wiring for CR10(X) Program Example
Description Color
CR10X
SDI-12 data
Green
C8
SDI-12 power
Red
+12 Vdc
SDI-12 reference
Black
G
Shield Clear
G
;{CR10X}
;
*Table 1 Program
01: 1.0000 Execution
Interval
(seconds)
1: SDI-12 Recorder (P105)
1: 0
SDI-12
Address
2: 20
Continuous
Measurements
(aR0!)
3: 8
Port
4: 1
Loc [ wnd_dir ]
5: 1
Mult
6: 0
Offset
2: Z=F x 10^n (P30)
1: 1
F
2: 0
n,
Exponent
of
10
3: 4
Z Loc [ samples ]
3: If (X<=>F) (P89)
1: 1
X Loc [ wnd_dir ]
2: 4
<
3: -99990 F
4: 30
Then
Do
4: Block Move (P54)
1: 2
No.
of
Values
2: 1
First Source Loc [ wnd_dir ]
3: 1
Source
Step
4: 2
First Destination Loc [ wnd_spd ]
5: 1
Destination
Step
5: End (P95)
6: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 30
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)
7: Real Time (P77)
1: 110
Day,Hour/Minute
(midnight
=
0000)
17