1 array-based edlog dataloggers, Array-based edlog dataloggers – Campbell Scientific WINDSONIC 2-D Sonic Wind Sensors User Manual

Page 30

Advertising
background image

WindSonic Two-Dimensional Sonic Anemometer

Totalize (1,one,IEEE4,diag<>10)
FieldNames ("diag_10_TOT")

Totalize (1,one,IEEE4,diag<>NAN)
FieldNames ("nnd_TOT")
EndTable


BeginProg
one = 1

Scan (1,Sec,3,0)
SDI12Recorder (wind_direction,1,0,"R0!",1,0)
If ( wind_direction = NAN ) Then

wind_speed = NAN
diag = NAN

EndIf
disable_flag = (wind_direction=NAN) OR (diag<>0)

CallTable stats
NextScan
EndProg

7.5 Changing the SDI-12 Address Using LoggerNet and a

Datalogger

Up to ten WindSonic4s or other SDI-12 sensors can be connected to a single
datalogger control port. A datalogger can measure up to 4 WindSonic4 at 1
Hz. Each SDI-12 device must have a unique SDI-12 address between 0 and 9.
The factory-set SDI-12 address for the WindSonic4 is 0. The WindSonic4
SDI-12 address is changed in software by issuing the aAb! command, where a
is the current address and b is the new address, to the WindSonic4 over the
SDI-12 interface. The current address can be found by issuing the ?!
command.

A computer running LoggerNet can be used to issue any valid SDI-12
command through the datalogger to the WindSonic4. For a complete list of
SDI-12 commands supported by the WindSonic4, see Section 11 of the Gill
WindSonic manual.

7.5.1 Array-Based Edlog Dataloggers

• Connect a single WindSonic4 to the datalogger using Control Port p as

described in Section 7.2.3, SDI-12 Wiring, and download a datalogger
program that contains the SDI-12 Recorder (Instruction 105) instruction
with valid entries for each parameter.

• In the LoggerNet Toolbar, navigate to and activate the Test|Terminal

Emulator … menu. The “Terminal Emulator” window will open. In the
Select Device menu, located in the lower left hand side of the window,
select the station.

• Click on the Open Terminal button. If communications between the

datalogger and PC are successful, the red bar located in the upper left hand
side of the window will turn green.

• Click inside the “Terminal Emulator” window and press the <enter> key

until the datalogger responds with the “

∗” prompt (FIGURE 7-1).