Wesley BC-6200-8SA User Manual

Page 27

Advertising
background image

21

Curtis 1268 Manual,

Rev. D

THROT FAULT LO
The throttle fault low parameter sets the lower throttle fault threshold; throttle
input voltages below this threshold will signal a throttle fault.

THROT FAULT HI
The throttle fault high parameter sets the upper throttle fault threshold; throttle
input voltages above this threshold will signal a throttle fault.

3 — PROGRAMMABLE PARAMETERS: Current Limit Parameters

Current Limit Parameters

M1/M2 MAIN C/L
The main current limit parameter allows adjustment of the maximum current
the controller will supply to the motor during drive operation. This parameter
can be used to reduce the maximum torque applied to the drive system by the
motor in either of the modes. The drive current limit is adjustable from 100
amps up to the controller’s full rated current. The full rated current depends
on the controller model.

REGEN C/L
The regenerative current limit parameter allows adjustment of the maximum
current the controller will supply to the motor during regen braking opera-
tion. During regen braking, this parameter controls the regen current from the
motor’s armature into the battery. The braking current limit is adjustable from
0 amps up to the controller’s full rated current. The full rated current depends
on the controller model.

Regen is the normal mode of braking.

PLUG C/L
The plug current limit parameter allows adjustment of the maximum current
the controller will supply to the motor during plug braking operation. During
plug braking, this parameter controls the plug current from the motor’s armature.
The plug current limit is adjustable from 0 amps up to the controller’s full rated
current. The full rated current depends on the controller model.

Plug braking is used during WalkAway

and Anti-Rollback operation.

WALKAWAY C/L

The WalkAway current limit parameter sets the maximum field current

applied during WalkAway

operation. The WalkAway

function applies field

current to slow a vehicle that is detected as moving while the main contactor
is open. The motor force created from this function is intended to limit the
vehicle’s rolling speed, but may not be sufficient to slow heavy vehicles on steep

Advertising