NOMINAL

ARMATURE

FIELD

BATTERY

2 MIN

2 MIN

MODEL

VOLTAGE

RATING

RATING

NUMBER

(volts)

(amps)

(amps)

1268-54XX

36–48

400

50

1268-55XX

36–

48

500

50

SPECIFICATIONS: 1268 CONTROLLER

Nominal input voltage

36 V or 48V

PWM operating frequency

16 kHz

Electrical isolation to heatsink

500 V ac (minimum)

Logic enable and logic power input
voltage (minimum)

16.8 V

Logic enable and logic power input
current (no contactors engaged)

160 mA without programmer; 200 mA with programmer

Logic input voltage

>20.0 V High; <7.5 V Low

Logic input current

10 mA

Operating ambient temperature range

-40°C to 50°C (-40°F to 122°F)

Heatsink overtemperature cutback

starts at 85°C (185°F); cutoff at 95°C (203°F)

Heatsink undertemperature cutback

50% armature current at -25°C (-13°F)

Package environmental rating

IP64, IP67

Weight

3.9 kg (8.5 lb)

Dimensions (L×W×H)

229 Ч 178 Ч 81 mm (9.0" Ч 7.0" Ч 3.2")