High Standpipe Installation:

Place the hose into the standpipe. Remove the beaded

tie-down strap from accessories bag and place around

standpipe and drain hose, approximately 12 inches

(30 cm) down from the top of pipe and tighten strap to

hold hose to standpipe. This will prevent the drain

hose from dislodging from drain receptacle during use.

Figure 7

Low Standpipe Installation:

No. 562P3 Siphon Break Kit is required for this type

of installation. This kit is available (as optional

equipment at extra cost) through an authorized dealer

or parts distributor. Installation instructions are

supplied with the kit.

Figure 8

TLW1962N

1

Drain Hose

2

Standpipe (Standpipes higher than
4 feet [122 cm] are not recommended)

3

Tie-Down Strap

4

Standpipe Adapter

TLW1962N

2

1

3

4

W512I

1

562P3 Siphon Break Kit

2

Standpipe

3

Drain Hose

W512I

3

1

2