Water Supply Requirements

NOTE: Water supply faucets must fit standard
3/4 inch (19.1 mm) female garden hose couplings.
DO NOT USE SLIP-ON OR CLAMP-ON
CONNECTIONS.

NOTE: Water supply faucets should be readily
accessible to permit turning them off when washer
is not being used.

Figure 18

Water Temperature

Cold:

Recommended cold water temperature is 50° to 75°

Fahrenheit (10° to 24° Celsius).

Hot:

Recommended hot water temperature is 140° to

150° Fahrenheit (60° to 66° Celsius).

Warm:

Mixture of hot and cold water. (Warm water

temperature is dependent upon the water temperature

and the pressure of both the hot and cold water supply

lines.)

IMPORTANT: Turn off water supply faucets after
check-out and demonstration. Owner should turn
off water supply whenever there will be an
extended period of non-use.

NOTE: Longer fill hoses are available (as optional
equipment at extra cost) if the hoses (supplied with
the washer) are not long enough for the installation.
Order hoses as follows:

No. 20617 Fill Hose 8 feet (2.44 m)

No. 20618 Fill Hose 10 feet (3.05 m)

Water Pressure

Pressure must be a minimum of 20 to 120 pounds per

square inch (138 to a maximum of 827 kPa) static

pressure measured at the faucet.

NOTE: Water pressure under 20 pounds per
square inch (138 kPa) will cause an extended fill
time in the washer.

W187I

1

Water Supply Faucets

2

Cold Water Connection

3

Hot Water Connection

4

Fill Hoses

Under certain conditions, hydrogen gas
may be produced in a hot water system that
has not been used for two weeks or more.
HYDROGEN GAS IS EXPLOSIVE. If the hot
water system has not been used for such a
period and before using the washer, turn on
all hot water faucets and let the water flow
from each for several minutes. This will
release any accumulated hydrogen gas.
THE GAS IS FLAMMABLE, DO NOT SMOKE
OR USE AN OPEN FLAME DURING THIS
TIME.

W029

WARNING

C

H

2

1

3

4

WATER
MIXING

VALVE

Advertising