Figure 16, Grounding instructions, Figure 17 – Alliance Laundry Systems W001C User Manual

Page 14: Electrical requirements, Warning

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation

39239

12

Electrical Requirements

120 Volt, 60 Hertz with 3-Prong Grounding Plug

NOTE: The wiring diagram is located in the
control hood.

Figure 16

Grounding Instructions

The washer must be grounded. In the event of

malfunction or breakdown, grounding will reduce the

risk of electric shock by providing a path of least

resistance for electric current. The washer is equipped

with a cord having an equipment-grounding conductor

and a three-prong grounding plug. The plug must be

plugged into an appropriate outlet that is properly

installed and grounded in accordance with all local

codes and ordinances.

Do not modify the plug provided with the washer — if

it will not fit the outlet, have a proper outlet installed

by a qualified electrician.

NOTE: Have a qualified electrician check the
polarity of the wall receptacle. If a voltage reading
is measured other than that illustrated, the
qualified electrician should correct the problem.

Figure 17

D009I

To reduce the risk of fire, electric shock or
personal injury, all wiring and grounding
MUST conform with the latest edition of the
National Electrical Code, ANSI/NFPA 70,
and such local regulations as might apply. It
is the customer’s responsibility to have the
wiring, fuses and circuit breakers checked
by a qualified electrician to make sure your
home has adequate electrical power to
operate the washer.

W229

WARNING

D009I

DO NOT OVERLOAD CIRCUITS
DO NOT USE ADAPTER
DO NOT USE AN EXTENSION CORD

D090I

1

L1

2

Ground

3

Neutral Side

4

Round Grounding Prong

5

Neutral

Improper connection of the equipment-
grounding conductor can result in a risk of
electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the washer is properly
grounded.

W216

WARNING

STANDARD 120 VOLT, 60 HERTZ, 3 WIRE

EFFECTIVELY GROUNDED CIRCUIT

1

2

3

5

120 ± 12

V.A.C.

0 V.A.C.

120 ± 12

V.A.C.

4