Alto-Shaam FRYTECH SERIES ASF-75E User Manual
Page 19

Electric Fryer Operation & Care Manual • 17
O P E R A T I O N
Careful observation of the finished food product will
help determine optimal filtering frequency. Filtering
the cooking oil at regular intervals will help ensure
food quality.
FOR BEST RESULTS:
Do not allow the
temperature of the oil to decrease below the “Idle
Mode”
temperature of 250°F (121°C) when filtering.
If filtering at the end of the day, pump oil back into
the kettle while still hot. Do not allow oil to cool before
returning to kettle.
1.
Open the front access door. With the Nozzle
selector in the “KETTLE FILL” position, rotate
the drain valve counterclock-wise until rotation
stops and the drain valve is in the “OPEN”
position. Power to the main control panel will
automatically switch “OFF.”
2.
Allow contents of the fryer to completely drain.
3.
Press the PUMP “ON” to allow the oil to
circulate through the drain system to flush
crumbs. Using the brushes provided, brush the
sides and bottom of the fryer while the oil is
circulating through the system. Use the angle
brush under the heat exchangers.
4.
Press the PUMP “OFF” and allow contents of the
fryer to completely drain.
5.
Rotate the drain valve clockwise to the
“CLOSED”
position.
6.
Press the PUMP “ON” and allow the fryer
to refill to the recommended level adding
additional oil/shortening as required to
maintain proper fill level.
7.
After the frypot has completely refilled, pull out
the mobile oil trolley and discard the filter into
a proper receptacle. Clean the filter assembly
and oil trolley, if needed.
8.
Replace the oil filter and return the trolley to the
proper position beneath the fryer.
9.
Press and hold the “ON/OFF” key on
the main control panel for
1-1/2 to 2 seconds to energize
the fryer. Continue normal fryer operation
after the preheat function has been completed.
OIL FILTRATION INSTRUCTIONS (FOR UNITS WITH INSTALLED OPTION)
C A U T I O N
METAL PARTS OF THIS EQUIPMENT
BECOME EXTREMELY HOT WHEN
IN OPERATION. TO AVOID BURNS,
ALWAYS USE HAND PROTECTION
WHEN OPERATING THIS APPLIANCE.
ASF-75E, 120V WITH FILTRATION
oil
hi
-
limit
reset
nozzle
kettle
selector
nozzle
connection
master
power
switch
element
hi
-
limit
reset
pump
open
closed
kettle
drain
selector
element
hi
-
limit
alarm
C A U T I O N
OPERATORS MUST BE MADE AWARE OF THE HAZARDS
INVOLVED IN THE OPERATION OF A HOT OIL FILTERING
SYSTEM. ON-SITE SUPERVISION DURING THE
FILTRATION PROCESS AND THE CLEANING PROCESS IS
STRONGLY RECOMMENDED.
W A R N I N G
TO AVOID PERSONAL INJURY, USE
CAUTION WHEN SURFACES BECOME
SLIPPERY DUE TO SPILLED OR
DRIPPING OIL.