Port pinouts – Allied Telesis SwitchBlade x3106 User Manual
Page 38

Chapter 1: Overview
38
You may use straight-through or crossover cables on ports that are
connected to network devices that support automatic MDIX
detection and that operate at 10 or 100 Mbps.
You must use straight-through cables on ports that are connected
to network devices that have a fixed wiring configuration of MDI
and that operate at 10 or 100 Mbps.
You must use crossover cables on ports that are connected to
network devices that have a fixed wiring configuration of MDIX and
that operate at 10 or 100 Mbps.
Port Pinouts
Refer to Table 41 on page 258 for the port pinouts of twisted-pair ports
operating at 10 or 100 Mbps in the MDI configuration and Table 42 on
page 258 for the MDI-X configuration. For port pinouts for twisted-pair
ports operating at 1000 Mbps, refer to Table 43 on page 259.