Allied Telesis AT-S62 User Manual
Page 228

Chapter 12: Event Log and Syslog Servers
228
Section II: Advanced Operations
For example, the setting of DEFAULT assigns all port mirroring events
a code of 22 and all encryption key events a code of 4.
Your other option is to assign all events from a switch the same
numerical code using one of the following facility level settings:
1 - LOCAL1
2 - LOCAL2
3 - LOCAL3
4 - LOCAL4
5 - LOCAL5
6 - LOCAL6
7 - LOCAL7
Each setting represents a predefined RFC 3164 numerical code. The
code mappings are listed in Table 7.
9
Clock daemon
Time- based modules:
- TIME (system time and SNTP)
- RTC
22
Local use 6
Physical interface and data link
modules:
- PCFG
- PMIRR
- PTRUNK
- STP
- VLAN
23
Local use 7
SYSTEM events related to major
exceptions.
16
Local use 0
All other modules and events.
Table 7. Numerical Code and Facility Level Mappings
Numerical
Code
Facility Level Setting
17
LOCAL1
18
LOCAL2
19
LOCAL3
Table 6. Applicable RFC 3164 Numerical Code and AT-S62 Module
Mappings
Numerical
Code
RFC 3164 Facility
AT-S62 Module