Installation Instructions

If you need further assistance, or find that you are missing any parts, please contact the dealer from which you purchased this product.
We hope you enjoy your fixture!

* Hubbardton Forge will not be liable for injury or damage caused by improper installation, lamping or use of this fixture.

A351

Link Low Voltage Pendant 161040T

Page 3 of 4

Troubleshooting Guide: 12 Volt Pendant Lighting

Part 1. For Hubbardton Forge Track Lighting products that use the “Fast Jack Male Coaxial Fixture Connector” from

Edge Lighting, an Edge Lighting Installation Instruction “FJ-MC-_” is provided to the customer. This Instruction shows

one method for installing coaxial cable into the coaxial fixture connector. The method shown omits a trimming step to

the Braided Outer Shield, to simplify the installation.

Components:

A Coaxial Cable
B Coaxial Fixture Connector
C Conical Nipple
D Strain Relief Tube
E M4 Set Screw
F M3 Set Screw
G Inner Conductor
H Wire Insulation
I Braided Outer Shield

It has been determined that more consistent results can be obtained if:

1. The outer braided shield (I) of the coaxial cable (A) is stripped back 3/4" as shown in Figure 1.
2. The M3 Set Screw (F) is tightened until “Tight”, when the 1.5MM Allen Wrench starts to flex.

3. The M4 Set Screw (E) is tightened inward until it no longer causes an interference with the Conical Nipple (C). It will
begin to crush the Strain Relief Tube (D).
4. 3 Electrical Continuity tests are performed after assembly with a Digital Multi-Meter or Continuity Tester.

– Continuity Test #1 – Short Circuit test, tester should not light.

– Continuity Test #2 – Open Circuit test, tester should light.

– Continuity Test #3 – Functional Check. Same probe positions as Continuity Test #1, performed with Fixture

wired and a working bulb in the socket, tester should light.

Note: The M3 Set Screw (F) must make electrical contact with the Coaxial Cable Inner Conductor (G), yet the instructions do not call
for the inner conductor to be stripped back to expose the wire beneath. This is because the metal set screw pierces through the plas-
tic insulation as the set screw is tightened to full torque. However, if the tester will not light during test #3 it is recommended to strip
off 1/8” of insulation from the Coaxial Cable Inner Conductor (G). This will ensure that electrical connection is made.

(Continued)

(Figure 1- Coaxial Cable and connector Assembled)

(Figure 2- Continuity Test #1)

(Figure 3- Continuity Test #2)

L

B

H

C
I

F

C

E

D

A

3/4"

1/16"