Blodgett KLS-60G User Manual

Page 10

Advertising
background image

10

4.0 OPERATION

WARNING: In the event of main burner ignition failure, a 5 minute
purge period must be observed prior to re-establishing ignition
source.

WARNING: In the event you smell gas, shut down equipment at the
main shut off valve and contact the local gas company or gas
supplier for service.

CAUTION: If you smell gas during the lighting procedure,
immediately shut off the gas supply until the leak has been
corrected.


GAS CONTROL INSTRUCTIONS:

Appliance does not require “Lighting” the pilot with a flame.

A. STARTUP

1. Turn thermostat to “OFF” position and power switch to “OFF” position.

2. Open control panel access door located on right side at bottom.

3. Turn dial on combination control to “ON” position by rotating control knob counter clockwise.

(NOTE: Any gas service valves exterior to the unit should be open.)

4. Turn “POWER” switch to “ON” position.

5. Set “COOK TEMP” to desired setting. The red “COOKING” pilot will be on until desired

setting has been reached.

6. At this time the spark igniter will begin sparking at the pilot until the pilot is ignited, or for

ninety seconds (an audible clicking sound will be evident).

Contact the factory, the factory representative or a local service company to perform
maintenance and repairs should the appliance malfunction.

Advertising
This manual is related to the following products: