Blodgett KLS-60G User Manual

Page 8

Advertising
background image

8


2.0 INSTALLATION (Continued)

WARNING: Do not connect the appliance to the electrical supply until
after the gas connection has been made.

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is equipped with a three-prong (grounding) plug for
your protection against shock hazard and should be plugged directly
into a properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug. (120V units only).


120 VAC - 60 Hz - Single Phase

Units with this electrical rating are factory supplied with a three-wire cord and three-prong plug
which fits any standard 120V, three-prong grounded receptacle. A separate 15 amp supply is
needed for each unit.

208/240 VAC - 60 Hz - Single and Three Phase

Units with this electrical rating are factory equipped with a transformer. To connect supply wires
remove cover from transformer box at right rear of unit. Route supply wires and ground wire
through the hole in the cover with a strain relief fitting. Connect wires to the primary transformer
terminals as required by your power supply voltage. Connect ground wire to ground lug.
Replace cover. Three-phase units are wired as above, using only two supply wires. The third
supply wire is not connected and must be properly terminated.

220 VAC - 50 Hz - Single Phase

Units equipped with this voltage rating should be wired exactly as in (2) above.

Advertising