0 service connections – Blodgett KLS-60G User Manual

Page 4

Advertising
background image

4

1.0 SERVICE CONNECTIONS

KLS-20G-Total 100,000 BTU. One 1" male connection

(for location, see drawing below.) Natural Propane

Required operating pressure: Natural Gas 4" W.C.; Propane

Gas 10" W.C

- Total 100,000 BTU. One 1" male connection.

(for location, see drawing below.) Natural Propane

Required operating pressure: Natural Gas 4" W.C.; Propane

Gas 10" W.C

- Total 130,000 BTU. One 1" male connection

(for location, see drawing below.) Natura Propane.

Required operating pressure: Natural Gas 4" W.C.; Propane

Gas 10" W.C.

1

1

1

1

1

1

KLS-40G

GL-60E

UTILITY INFORMATION:

1

1

1

plug. Total maximum amps 2.0.

OPTIONAL: 208/60/1 or for use on 3 (190 to 219 volts) -

supply must be wired to unit - see drawing below. Total

maximum amps 1.0.

OPTIONAL: 240/60/1 or for use on 3 (220 to 240 volts) -

supply must be wired to unit - see drawing below. Total

maximum amps 1.0.

STANDARD: 115/60/1 - furnished with 6 ft. cord w/3-prong

ELECTRIC:

KLS-20G

KLS-60G

KLS-40G

MODEL

B

A

CAPACITY

inches

inches

inches

152 litres

227 litres

60 gallons

76 litres

40 gallons

20 gallons

660

mm

30

762

mm

20

26

508

mm

F

E

D

C

978

1118

1257

49.5

1016

42

1016

44

40

813

38.5

32

51

483

63

2.5

546

21.5

76

2

3

483

19

19

DIMENSIONS

J

H

G

737

1829

2159

85

889

35

1626

72

64

610

29

24

889

991

39

775

35

30.5

K

152

203

8.0

152

6.0

6.0

1016

40

902

35.5

31.25

794

L

464

18.25

559

22

625

24.62

UNITS

6(152)

H

D

CLOSED 5.5(140)

OPENED 7.5[191]

E

STANDARD

Ø 2(51] VALVE

GC

EC

J

C

B

L

K

GC

EC

G

F

ØA

EC

GC

KLS-20G = Ø 20.75"

KLS-40G = Ø 26.75"

KLS-60G = Ø 30.75"

FRONT

120° X 3

DIMENSIONS ARE IN INCHES [MM]

GAS:

Advertising