Swiftech H20 220 APEX ULTRA REV2 User Manual
Page 23
Copyright Swiftech 2007 – All rights reserved – Last revision date: 10-08-07 - Information subject to change without notice – URL:
http://www.swiftech.com
Rouchon Industries, Inc., dba Swiftech – 3700 Industry Avenue, Suite 104, Lakewood, CA 90712 – Toll free (US) 888-857-9438 – Fax 562-595-8769 - E Mail:
PAGE 23 of 24
7.
T
ROUBLESHOOTING
Air keeps circulating into the circuit, long after the pump has primed:
o
There is a significant pocket of air trapped into the circuit. In most cases this will be due to the fact that the radiator
and or the water-block where installed upside down. Temporarily dismount the device and re-orient right side-up until
all the air has escaped back into the circuit.
o
The fluid level is too low: top-off the reservoir to the appropriate level.
o
One of the components connections is loose, or improperly tightened: Inspect each connection for traces of
moisture, and tighten all worm-drive clamps, and various connections in the circuit.
The pump does not prime.
It is likely that the circuit is not installed correctly. Please check that the reservoir discharge is duly connected to the pump inlet.
Reminder: do not let the pump run dry.
The Coolant is filled with debris of some sort:
Despite our best efforts, such as lengthy ultrasonic cleaning of the radiator, and careful inspection and cleaning of all the parts
we manufacture, it is always possible that debris or some sort may be contaminating your circuit. When this happens it will
significantly affect the performance of the APOGEE water-block, which mini-jets can be easily obstructed due to their small
size. The circuit should then be completely flushed (see draining procedure below), and the APOGEE water-block should be
disassembled for inspection and cleaning.
8.
D
RAINING THE SYSTEM
Open up the fill-cap from the MCRES-Micro
Then, you will need to disconnect a line from one of the lowermost components. Typically, this would be the pump. You
need to procure a bucket large enough to receive approximately 1 liter of fluid, and place the bucket underneath the
connection that you intend to “break”. Disconnect the line, and place both ends into the bucket, until all the liquid is
drained from the system.
9.
P
ERIODIC
M
AINTENANCE
Every 6 months: dust off the radiator fins and fan. You can use a can of compressed air for example, available
in most electronic supply stores. If you live in a very dusty area, you should perform this task at closer intervals.
It is essential to maintain the optimum performance of your cooling system.
Inspect the liquid level inside the reservoir, and refill if necessary (no refills are normally necessary for 18
months of continuous usage). Evaporation in this closed circuit is extremely limited, but still present due to
some permeability in the vinyl lines.
10.
O
PTIONAL
C
OMPONENTS
Liquid Cool your high-end SLI VGA with the
MCW55™
To use this water-block with the 7/16" tubing shipped with the Apex
kit, please use the
1/2" Tube ID Hose barb adapters
- Part #
PI251616S "Fitting: 1/2 in. Stem to 1/2 in. barb"
Notes: flow-wise, these fittings are equivalent to standard brass
1/2" barbs. The red clip is also provided to prevent any accidental
removal of the fitting during operations.
Cool the graphics memory with our
MC14
Ramsinks