1. MCW5002-775T™ THERMOELECTRIC WATER-BLOCK INSTALLATION GUIDE FOR INTEL

® PENTIUM®

4 (LGA775)


Figure 1


A. Preparing the motherboard

Remove the stock heatsink retention mechanism to reveal the
four-motherboard mounting holes.

Install a standoff in each one of the holes. As the diameter of
the mounting holes is usually larger than the diameter of the
standoff stem, be careful to keep the standoff approximately
centered in the MB holes. Secure the standoffs with the
provided hex locknuts, and a fiber washer on the backside of
the MB as shown on fig. 1, using the tools described fig. 2

Figure 2

Use a ¼” socket tool to drive the standoff, and a small pair of
pliers to prevent the locknut from spinning. Torque value should
not to exceed 16 in. lbs. In other words JUST FIRM AND
TIGHT, BUT WITHOUT EXCESSIVE TORQUE.