LIMITED WARRANTY

PerTronix, Inc. warrants to the original Purchaser of its Flame-Thrower billet dis-

tributor that the product shall be free from defects in material and workmanship (nor-

mal wear and tear excluded) for a period of 12 months from the date of

purchase.

If within the period of the foregoing warranty PerTronix finds, after inspection, that

the product or any component thereof is defective, PerTronix will, at its option, repair

such products or component or replace them with identical or similar parts PROVIDED

that within such period Purchaser:

1. Promptly notifies PerTronix, in writing, of such defects.

2. Delivers the defective product or component to

PerTronix (Attn: Warranty) with proof of purchase date; and

3. Has installed and used the product in a normal and proper

manner, consistent with PerTronix printed instructions

THE FOREGOING LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF

ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING ANY

IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE.

THE FURNISHING OF A REPAIR OR REPLACEMENT COMPONENT

OR COMPONENTS SHALL CONSTITUTE THE SOLE REMEDY OF PURCHASER

AND THE SOLE LIABILITY OF PerTronix WHETHER ON WARRANTY, CONTRACT

OR FOR NEGLIGENCE, AND IN NO EVENT WILL PerTronix BE LIABLE FOR

MONEY DAMAGES WHETHER DIRECT OR CONSEQUENTIAL.

440 East Arrow Highway

San Dimas, CA 91773

909-599-5955

www.pertronix.com

0017-004422

10-13

DISTRIBUTOR INSTALLATION
INSTRUCTIONS FOR:
BRITISH DISTRIBUTORS

GENERAL INFORMATION
1. IMPORTANT: Read all instructions before starting installation.
2. For

12-volt negative ground systems only.

3. New spark plug wires may be required.
4. Solid core spark plug wires

MUST NOT be used.

DISTRIBUTOR REMOVAL
1. Crank the engine until the first cylinder in the firing order is at TDC "Top Dead

Center" on its compression stroke. The timing indicator should point to TDC or 0.

2. Remove the distributor cap, and make sure that the rotor is pointing towards the

contact on the distributor cap for the first cylinder in the firing order.

3. Disconnect the battery cable.
4. Disconnect all wires and hoses attached to the distributor.
5. Remove the distributor hold down bolt.
6. Remove the distributor from the engine.
7. Check the distributor drive for signs of excess wear, or potential problems.

DISTRIBUTOR INSTALLATION

Note: Original hold down clamp must be used with new Flame-Thrower

distributor. Hold down bracket must be free of paint and corrosion, this will insure

that a proper ground is made to the engine block.

1. Remove the Flame-Thrower distributor cap.

2. Turn the shaft so that when the distributor is placed into the engine, the rotor

position matches that of the original distributor.

3. Press the distributor down into the engine block. Make sure that the drive dog

lines up and is engaged fully. Misalignment can cause permanent damage to the

engine as well as the distributor.

4. Place the distributor cap onto the housing.
5. Turn the distributor housing so that the terminal that represents the first cylinder

in the firing order, lines up with the rotor contact terminal.

6. Tighten the distributor clamp and hold down bolts to the engine.
7. Clip the cap into place and install the spark plug wires in the proper firing order.

8. For Vacuum advance distributors:

Locate the vacuum hose that was previously attached to the vacuum advance
canister. This hose should originate at a ported vacuum source. Some applica-
tions have vacuum advance hoses attached to a manifold vacuum source, due
to the performance advance curve, we recommend that you relocate this hose

For Part Numbers:

D170600

D170609

D170618

D170619

D171618

D171600

D174218

D174219

D174228

D174229

Recommended Flame-Thrower II & HV Coils:

Application

Primary resistance

Chrome

Black

Epoxy

Ignitor II Only

0.6 ohm

45001

45011

45111

Ignitor II Only

0.45 ohm

E-Core HV Coil

60104

NOTE: REMOVE OR BYPASS EXTERNAL BALLAST RESISTOR OR RESISTANCE WIRE WHEN
INSTALLING THE RECOMMENDED FLAME-THROWER II OR HV E-CORE COIL.