Miracle steamer, Maintenance (continued) – A.J. Antunes & Co MS-255 9100468 User Manual

Page 13

Advertising
background image

Miracle SteaMer

13

P/N 1010455 Rev. D 03/12

A.J. Antunes & Co.

7. using a sponge or a dry towel, remove the

delimer solution from the generator surface, then

rinse with clean water.

monthly

the Miracle steamer utilizes an open steam generator.

Water sprayed onto the generator surface flashes into

steam immediately, but the minerals in the water do not

steam, they stay on the generator surface.

a small

amount of calcium/mineral deposits are needed for

proper operation, but a buildup of excessive calcium/

mineral deposits causes poor steaming efficiency and

excessive moisture (wet steam), which will eventually

severely hinder the steaming action.

cleaninG steam GeneratOr
1. turn the power off, unplug the power cord, and

allow the unit to cool down.

2. Perform the Daily cleaning, but do NOt

reassemble the unit.

3. Remove the Wing Nut, generator cover, and

Diffuser (figure 11). Wash these items in hot,

soapy water, rinse and

wipe DrY.

4. With the unit cool, use a wire brush and/or

scraper to loosen and remove the excessive cal-

cium/mineral deposits from the generator

surface.

5. take a wire brush and clean out any buildup from

the 28 steam Ports (26 vertical and 2 horizontal)

of the generator (figure 11). Remove the loose

buildup, wipe the generator with a clean, damp

cloth, and reassemble the unit.

nOte: if deposits are still excessive and/or diffi-

cult to remove, refer to steps 6 and 11.

6. Pour delimer solution (not supplied) onto the

generator surface. follow the delimer manufac-

turer’s instructions for proper mixture and use.

caUtiOn

if a chemical cleaner/delimer is used, be sure it is

safe to use on cast aluminum. Observe all pre-

cautions and warnings on the product label.

maintenance (continued)

nOte: to ensure proper steaming characteristics,

some calcium/mineral deposits must be present on

the Generator surface. if, during cleaning, the sur-

face does become free of calcium/mineral deposits,

add plain tap water to the surface and allow it to

boil off. if necessary, repeat this process to formu-

late a thin coating of calcium/mineral deposits.

nOte: in soft water areas, it may be necessary

to add a small amount of lime to the Generator to

“season” it. this will ensure proper steaming char-

acteristics by producing a thin coating of calcium/

mineral deposits on the Generator surface.

seasoning mixture consists of 3/4 ounces (25ml/

25cc) baking soda, 3/4 ounces (25ml/25cc) lime

mixed with 1 quart (950ml/950cc) of water. stir

mixture and pour 1/4” deep onto the hot Generator

surface. after mixture is converted to steam, the

remaining loose power can be removed.

8. Plug the power cord into the appropriate outlet.

9. turn the power on and allow the unit to warm up

for approximately 30 minutes.

10. Push and release the

Operate button or the

start/stOp button several times to operate the

steamer.

this purges any remaining delimer

residue from the Generator surface.

11. turn the power off, reinstall all parts and acces-

sories, and return the unit to service.

READ

Y

Diffuser

wing nut

Generator

cover

figure 11. monthly cleaning

Generator

steam ports

(26 vertical and

2 horizontal)

Advertising