figure 4. connecting water supply

installatiOn (continued)

plumbing

nOte: miracle steamer models are designed to

use cold tap water. Distilled water may be used to

reduce calcium/mineral deposit buildup and reduce

maintenance costs.
these units require a direct cold water hookup. a Water

inlet Hose and strainer assembly (figure 4) is supplied.
nOte: incoming water is controlled by a normally

closed (nc) solenoid valve located inside the

steamer’s electrical housing.
1. turn off the water valve (not supplied) that sup-

plies water to the unit (figure 4).

2. connect the 1/4” (6.5 mm) i.D. flexible tubing to

the outlet side of the Water Pressure Regulator

and secure using the Worm clamp (figure 4).

nOte: a water pressure regulator must first be

installed (figure 4). failure to do so will result

in poor steaming and possible flooding. for a

single steamer, use water pressure regulator p/n

7000314. For two adjacent steamers, use Water

pressure regulator p/n 7000235.

caUtiOn

water pressure must not exceed 30 psi (2.1 kg/cm2

or 207 kpa). higher pressure may cause poor per-

formance or flooding. to reduce water pressure,

install a water pressure regulator, and set to

20–25 psi (1.4–1.7 kg/cm2 or 138–172 kpa).

3. turn the water valve on.
4. Hold the Quick Disconnect insert over a bucket,

then press and hold the white plastic tip until

there’s a good, steady water flow. this will purge

all air out of the line.

5. Release the plastic tip and check the pressure on

the Water Pressure Regulator. it should read

20 psi.

a.) if it reads less, increase the water pressure by

pulling the black knob up and turning it clockwise.

b.) if it reads more, decrease the water pressure

by pulling the black knob up and turning it counter

clockwise.

NOTE: When adjusting the knob, relieve the exist-

ing pressure by pressing the plastic tip on the

Quick Disconnect insert for 3 seconds. the water

pressure regulator will then show the new pressure.
6. Once the regulator reads 20 psi, push the black

knob down to lock it in place.

7. Push the Quick Disconnect insert into the fitting at

the rear of the unit until it clicks (figure 4).

Connect Quick

Disconnect

Insert Here

Inlet Hose & Strainer

Assy. (Supplied)

Optional Water Pressure Regulator

with Strainer (P/N 7000314)

Shut Off Valve

(Not Supplied)

Cold

Water

Flow

Flexible Nylon Braided

1/4 " I.D. Tubing (Not Supplied)

Quick

Disconnect

Insert

Worm

Clamp

NOTE: The use of only one strainer is

acceptable instead of two.

caUtiOn

this equipment is to be installed to comply with

the basic plumbing code of the building Officials

and code administrators, inc. (bOca) and the

food service sanitation manual of the food and

Drug administration (fDa).

Advertising