Installation (continued), A.j. antunes & co – A.J. Antunes & Co UFL-440 9700479 User Manual

Page 10

Advertising
background image

UFL-420/440 water FiLtration system

10

P/N 1010873 Rev. G 03/12

A.J. Antunes & Co.

figure 4. proper Draining

2” (5.1 cm)

minimum

2” (5.1 cm)

minimum

floor

Drain

secure

end

Drain line

from system

Drain line

from system

secure

end

Drain

standpipe

InstallatIOn (continued)

9. once again, press and hold the Program button

for at least 60 seconds to flush out any remaining

air from the system.

10. Release the Program button. Flushing is

complete.

sanItIzInG tHe system anD lInes

The plumbing must be sanitized to eliminate possible

contamination that may have occurred during the instal-

lation process. Chlorine bleach can be used to sanitize

the plumbing. The amount of bleach to use depends on

the system installed and the amount of plumbing down-

stream of the filter system. Generally, one ounce (30

ml) of bleach will be sufficient to sanitize the system.

1. Make sure that the system has been flushed of

air and debris as described in the Flushing and

Starting up the System section of this manual.

2. open the tap closest downstream to the filter sys-

tem.

3. Close the inlet water valve and allow the system

to depressurize.

4. Place a bucket under the “T” or cross fitting at

the inlet connection to the system. open the inlet

drain valve or unscrew the cap to drain the sys-

tem.

5. Press and hold the Program button to help drain

the system.

6. When the water flow out of the inlet fitting stops,

close the inlet drain valve and pour the liquid

bleach into the inlet connection fitting. Be careful

not to spill bleach onto clothing or skin. You may

want to add the bleach using a cup. Reattach the

cap on the fitting.

6. Slowly open the inlet water valve and allow water

to flow out of the tap until the smell of bleach is

present.

7. Close the tap and let the system stand with no

water flow for at least 15 minutes to allow the

bleach to sanitize the pipes.

8. After 15 minutes without water flow, open the tap

and flush until the presence of bleach is gone. All

other taps should be opened to flush any bleach

from the plumbing. Close the taps.

9. Press and hold the Program button for at least 60

seconds to complete the flushing process.

10. Sanitation is complete.

Program the timer following the procedure outlined in

the operation section of this manual.