InstallatIOn (continued)

locating and mounting the system

Consider these points before mounting the system:

• Note the location of the water supply, drain, and

an appropriate electrical outlet when choosing a

mounting location.

• Remember to allow for access to the timer/

programmer controls.

• Do not mount the system above any electrical

equipment, or items that may be damaged if they

get wet.

• Install the system in a location that will allow for

future service access. Cartridge replacement will

be either through the top or bottom of the housing.

nOte: be sure to allow access to both the top and

bottom of the housing.

• Mount the system on a wall using appropriate

mounting hardware.

• Remember to consider the operating weight of

the system when choosing mounting hardware.

Depending on the type of wall the system is being

mounted to, wall reinforcement may be necessary.

Mount the filtration unit using the Mounting Bracket

(Figure 2) using 1/4” by 1” bolts or bolts of the metric

equivalent.

Inlet water plUmbInG

It is recommended that the inlet water plumbing line be

1” NPT or larger. A shutoff valve (not supplied) should

be installed in the line leading to the system. The valve

should be mounted close to the system inlet and sized

properly for the inlet plumbing line.
It is also recommended that a “T” or cross Fitting (with

cap or plug) be installed between the inlet valve and the

system Inlet. This fitting can be used for draining and

sanitizing the system and downstream plumbing.
The system should only be connected to the cold water

line.
To ensure that the highest quality water is produced

from the system, the plumbing leading to the filter

system must be flushed clear of all debris before the

system is hooked up. Before making the connection to

the inlet of the filter system, hold a bucket or other con-

tainer at the inlet water line and slowly open the inlet

water valved. Allow the pipe to flush until all debris is

removed.

permeate lIne plUmbInG

To ensure the highest quality and safest water, it is

recommended that a check valve (to prevent backflow)

be installed in the water line after the permeate connec-

tion. This will help prevent possible contamination of

the filter system due to other equipment downstream.

The check valve (not supplied) should be mounted

close to the system outlet, and sized properly for the

plumbing line. Check with local codes for the proper

specification.
A shutoff valve (not supplied) should be installed in the

filtered water line leading from the system. The valve

should be mounted close to the system outlet and sized

properly for the plumbing line. This valve will allow for

easier servicing and future cartridge change out.

Filter

Base

Flow Control

(supplied,

see inset)

Inlet Drain

Valve (not

Supplied)

Sanitation

Plug (not

supplied)

Inlet Water

Valve (not

supplied)

Incoming

Water

Supply

figure 3. Inlet water plumbing

Flow Controller

(Green for UFL-420,

Black for UFL-440)

Into

Filter

Base

Inset

water flow

ImpOrtant

commonwealth of massachusetts plumbing code

248 cmr shall be adhered to. the use of saddle

valves are not permitted, please consult your local

plumber.