background image

-

4 - LXE700 SPOT

Installation via the Omega U Brackets.

1

2

3

4

(1)Omega-holders

(2)C lamp

(3)Safety -rope

(4)Quic k -loc k fas tener



Screw one clamp (the clamp is not provided with LXE 700 Spot) onto each of the two Omega U brackets
supplied with LXE 700 Spot.
Insert the quick-lock fasteners of the first Omega bracket into the respective holes on the bottom of LXE 700
Spot

. Tighten the quick-lock fasteners fully clockwise. Install the second Omega U bracket. Please do not use

pliers, crest wrenches and the like to turn the quick-lock fastener. If you do, there is very real likelihood that you
will break the Omega bracket. (These can be replaced at a substantial cost to your boss!)
Pull the safety cable through the holes on the bottom of the base and over the trussing or any secondary fixing
point. Do not clamp the cable to the U bracket or clamp. That is not a secondary safety point.
A secondary safety point is any point that will adequately hold LXE 700 Spot if the U brackets, clamps or the
fixtures base breaks or fails. Then the safety cable would be the backup and stop the fixture from falling to the
ground.