Faults without display on the console

Fault

Possible cause

Remedy

By whom

No display inspite of
power switch in posi-
tion 1

Mains Plug not connected to the socket.

Insert the mains plug into a socket.

Operator

Fuse F1 blown

Remove the side panel and unlock the fuse F1 by
pressing on it.

Operator

No compressed air jet
despite the trigger be-
ing drawn

Compressed air supply has too little pressure Check pressure level.

Operator

Jet pressure is set too low

Set the jet pressure to a higher level.

Operator

Power supply has been interrupted

Check power supply. Indicator lamp "Device on"
must glow green.

Operator

Emergency-stop button has been pressed.

Release emergency-stop button by turning. Indi-
cator lamp "Device on" must glow green.

Operator

Control cable not connected properly

Check connection between control cable and the
jet pistol and between the control cable and the
device.

Operator

Control cable is defective

Replace spray agent hose.

Operator

Compressed air jet is
too weak

Jet pressure is set too low

Set the jet pressure to a higher level.

Operator

Compressed air supply has too little pressure
or the compressor output is low.

Check pressure and output.

Operator

The filter insert in the water separator is
plugged.

Replace the filter inlay in the water separator.

Operator

Spray agent hose or jet pistol is blocked

Let the spray agent hose and jet pistol come to
room temperature and remove the blocking. In-
crease working pressure and / or reduce the dry
ice dosing.

Operator

No dry ice pellets in the
compressed air jet

Dry ice dosing switched off (with jet pistol Ad-
vanced only), "Dry ice dosing on/off" button
on the jet pistol illuminates red, display shows
"Ice off".

Press the dry ice dosing key on the Advanced jet
pistol.

Operator

Dry ice container is empty

Refill the dry ice container

Operator

Dry ice has melted

Empty the dry ice container and refill it with fresh
dry ice pellets.

Operator

Vibrator on the dry ice container is not work-
ing

Call Customer Service.

Operator

Drive motor of the dosing equipment is over-
loaded

Let the dosing thaw

Operator

Compressed air is exiting into the dry ice con-
tainer

Clean the pressure balance channel in the dosing
equipment.

Customer
Service

Dosing disc in the dosing unit is defective

Replace the dosing disc.

Customer
Service