Note
A sample bundle of liquid softener is includ-
ed

Remove spring (c) from the lid support
(b) of the softener tank (a).

Fill the tank with Kaercher softener liq-
uid RM 110 (Order no. 2.780-001).

The liquid softener prevents the calcifi-
cation of the heating spiral while operat-
ing with calciferous tap water It is dosed
into the supply drop by drop

The metering is set to medium water ri-
gidity by the manufacturer

ƽ

Danger

Risk of electrical voltage! Setting may only
be done by an electrician.

Determining the hardness of tap water:

through the public water supply works,

using a hardness tester (order no.
6.768-004)

Open the electrical box.

Set the speed potentiometer (a) accord-
ing to the water hardness. You can refer
to the correct setting in the table.

Example:
For a water hardness of 15 °dH, set 7 on
the value scale of the speed potentiometer.

Please observe the following warning notes
when handling batteries:

Refill liquid softener

Adjust dosing of liquid softener

Water hardness
(°dH)

Scale on the speed
potentiometer

5

10

10

8

15

7

20

6,5

25

6

30

5,5