Ai-900ms master station interface card connection, View, Press-to-talk [ptt] key transfer [xfer] key – Aiphone AI-900 User Manual

Page 23

Advertising
background image

23

12.3. AI-900MS Master Station Interface Card Connection

12.3.1. Master Station and AI-900MS connection

• The AI-900MS can be interfaced with up to 2 AI-MS900 master stations.
• Because up to 2 AI-900MS cards can be mounted in the AI-900MF Main Frame, up to four master stations

can be connected per frame.

• A station address must be assigned to each connected AI-MS900 station. Set the station address at each

AI-MS900 station after switching ON the power.

[Station Address Setting]

Step 1. Set the Master Station's REGISTER switch to the ON position. The "Reg_mode" indication will be

displayed on the station screen.

Step 2. Press the [XFER] key.

Step 3. According to the following table, enter the station address 1 – 4 through the use of a numeric keypad.

AI-900MS

Line

Station Address

MS/AL Slot 1

1

1

2

2

MS/AL Slot 2

1

3

2

4

Step 4. Press the [PTT] key.

Step 5. Set the REGISTER switch to the OFF position to places the station in standby mode.

Press-to-talk [PTT] key

Transfer [XFER] key

2

ABC

1

3

DEF

1

2

3

4

5

6

7

8

5

JKL

4

GHI

6

MNO

8

TUV

7

PRS

9

WXY

0

C

OPER

P T T

REDIAL

XFER

#

HANDSET

REGISTER

Do not connect thei jack
to telephone line.

LINE

MINI.

MAX.

SP. VOL.

OFF ON

[View ]

A

View

A

Registration ON/OFF switch
[REGISTER ON/OFF]

Display panel

Numeric keys
[0] – [9]

Advertising