Safety warnings

for user

• Always cover lighted elements, to prevent excess heat from

damaging the appliance. In the case of oil, gas and coal fired
cookers it is essential to avoid open flames.

• Also, when frying, keep the deep frying pan on the cooker top/

cooker under careful control.

• The hot oil in the frying pan might ignite due to overheating.
• The risk of self-ignition increases when the oil being used is dirty.
• It is extremely important to note that overheating can cause a fire.
Never carry out any flambé cooking under the hood.
Always disconnect the unit from the power supply before

carrying out any work on the hood, including replacing the
light bulb
(take the cartridge fuse out of the fuse holder or switch
off the automatic circuit breaker).

It is very important to clean the hood and replace the filter at

the recommended intervals. Failure to do so could cause
grease deposits to build up, causing a fire hazard.

for kitchen unit installer

• When used as an extractor unit, the hood must be fitted with a

150mm diameter hose.
Falls ein Abluftrohr in Wand oder Dach mit einen Durchmesser von
125 mm schon besteht, kann der mitgelieferte Reduzierstutzen,
150/125 mm, verwendet werden. Zusammen mit dem
Reduzierstutzen kann der Ablaufschlauch 125 montiert werden.

When installing the hood, make sure you respect the following

minimum distance from the top edge of the cooking hob/ring
surfaces:
electric cookers

600 mm

gas cookers

650 mm

coal and oil cookers

700 mm min.

• The national decree on fuel-burning systems specifies a maximum

depression of 0.04 bar in such rooms.

• The air outlet must not be connected to chimney flues or combus-

tion gas ducts. The air outlet must under no circumstances be
connected to ventilation ducts for rooms in which fuel-burning
appliances are installed.