Grease filter led (d), Activated charcoal filter led (e), Resetting the saturation indicator – AEG DI 8610 User Manual

Page 9

Advertising
background image

80

Control device for grease and activated charcoal
filters

This hood is fitted with a device that signals when it is necessary to
clean the grease filter or the activated charcoal filter (in the case of
recirculation version with activated charcoal filter).
On delivery, the hood is not supplied with an activated charcoal filter,
so the saturation indicator will be disabled.
If the hood is to be used with an activated charcoal filter, the saturation
indicator light must be enabled as follows:
Press buttons B and G simultaneously and hold them for 3 seconds.
At first only the grease filter LED D will light up, but when the activated
charcoal filter LED D lights up the saturation indicator will be enabled.
To disable it: Press buttons B and G again simultaneously and hold
them for 3 seconds, until the activated charcoal filter LED goes out.

Grease filter LED (D)

LED D will start to flash when it is time to clean the grease filter.
Cleaning will be necessary after 40 working hours. Always comply
with
the maintenance instructions for the grease filter (see page 13).

Activated charcoal filter LED (E)

The activated charcoal filter LED E will start to flash when the
activated
charcoal filter needs to be replaced. This operation is necessary after
approximately 160 working hours.
(Please see page 13 for instructions on Cleaning/replacing).

Resetting the saturation indicator

After cleaning the filters, press button A for 3 seconds until the grease
filter LED D or the activated charcoal filter LED E stops flashing.

Advertising