Self-diagnosis display – Sony DCR-TRV38 User Manual

Page 186

Advertising
background image

186

C:21:00

Self-diagnosis display

5-digit display

Cause and/or Corrective Actions

• You are using a battery pack that is not an

“InfoLITHIUM” battery pack.

c Use an “InfoLITHIUM” battery pack (p. 192).

• Moisture condensation has occurred.

c Eject the cassette and leave your camcorder for at least

one hour to acclimatize (p. 197).

• The video heads are dirty.

c Clean the heads using the cleaning cassette (optional)

(p. 198).

• A malfunction other than the above that you can service

has occurred.

c Eject the cassette and insert it again, then operate your

camcorder. Do not perform this operation if moisture
starts to condense (p. 197).

c Disconnect the power cord of the AC Adaptor or

remove the battery pack. After reconnecting the power
source, operate your camcorder.

c Replace the cassette.

• A malfunction that you cannot service has occurred.

c Contact your Sony dealer or local authorized Sony

service facility and inform them of the 5-digit code.
(e.g. E:61:10)

If you are unable to rectify the problem even if you try corrective actions a few times,
contact your Sony dealer or local authorized Sony service facility.

Your camcorder has a self-diagnosis display
function.
This function displays the current condition
of your camcorder as a 5-digit code (a
combination of a letter and figures) on the
LCD screen, viewfinder or display window.
If a 5-digit code appears, check the following
code chart. The last two digits (indicated by
ss

) will differ depending on the state of

your camcorder.

LCD screen, Viewfinder or
display window

Self-diagnosis display

• C:ss:ss

You can service your camcorder
yourself.

• E:ss:ss

Contact your Sony dealer or local
authorized Sony service facility.

C:04:ss

C:21:ss

C:22:ss

C:31:ss
C:32:ss

E:20:ss
E:61:ss
E:62:ss